首頁(yè) > 產(chǎn)品中心 > 科研抗體 > 標(biāo)記二抗
產(chǎn)品中心
相關(guān)產(chǎn)品
標(biāo)記二抗
英文名稱Rabbit anti-mouse Kappa light chain/Alexa Fluor 350
中文名稱:Alexa Fluor 350標(biāo)記的兔抗小鼠k鏈
別 名Ig kappa chain C region; HCAK 1; HCAK1; Ig kappa chain C region; IGKC; Immunoglobulin kappa constant; Immunoglobulin kappa constant region; Immunoglobulin kappa light chain; Kappa 1 immunoglobulin light chain; kappa light chain; Km; MGC111575; MGC62011; MGC72072; MGC88770; MGC88771; MGC88809.
規(guī)格:0.1ml
說(shuō) 明 書(shū)0.1ml
抗體來(lái)源Rabbit
克隆類型Polyclonal
交叉反應(yīng) IgG
產(chǎn)品應(yīng)用IF=1:100-1000
not yet tested in other applications.
optimal dilutions/concentrations should be determined by the end user.
分 子 量25kDa
性 狀Lyophilized or Liquid
濃 度2mg/1ml
免 疫 原KLH conjugated synthetic peptide derived from mouse Kappa li
亞 型IgG
純化方法affinity purified by Protein A
儲(chǔ) 存 液0.01M TBS(pH7.4) with 1% BSA, 0.03% Proclin300 and 50% Glycerol.
保存條件Storage: Store at –20 oC for one year. Avoid repeated freeze/thaw cycles. The lyophilized antibody is stable at room temperature for at least one month and for greater than a year when kept at -20oC. When reconstituted in sterile distilled water or diluent supplied, theantibody is stable for at least two weeks at 2-4 °C.
產(chǎn)品介紹background:
Immunoglobulins belong to a group of related glyco proteins which make up 20% of serum proteins. Antigens and immunoglobulins react to confer immunity to individuals. Immunoglobulins have similar structures of two identical heavy chains and two identical light chains. Both the heavy chains and the light chains are divided into constant and variable regions. The constant regions have the same amino acid sequences between all the immunoglobulin classes. The variable regions have approximately 110 amino acids with high sequence variability. The amino acid sequence of the heavy chain determines the class of an immunoglobulin. The five types of immunoglobulin heavy chains are known as: IgG, IgA, IgM, IgD, and IgE. IgG is divided into four subclasses, and IgA is divided into two subclasses. In serum IgA and IgG are monomers with a single 4 polypeptide unit; while, IgM is a pen tamer. IgA may also form polymers. Kappa light chain antibody can be used for the identification of leukemias, plasmacytomas and certain non Hodgkin's lymphomas. Kappa light chain contains one immunoglobulin like domain. The EU sequence has the INV allotypic marker, Ala 45 and Val 83. The ROY sequence has the INV allotypic marker, Ala 45 and Leu 83.
Important Note:
This product as supplied is intended for research use only, not for use in human, therapeutic or diagnostic applications.
中文名稱:Alexa Fluor 350標(biāo)記的兔抗小鼠k鏈
別 名Ig kappa chain C region; HCAK 1; HCAK1; Ig kappa chain C region; IGKC; Immunoglobulin kappa constant; Immunoglobulin kappa constant region; Immunoglobulin kappa light chain; Kappa 1 immunoglobulin light chain; kappa light chain; Km; MGC111575; MGC62011; MGC72072; MGC88770; MGC88771; MGC88809.
詳細(xì)介紹:
規(guī)格:0.1ml
說(shuō) 明 書(shū)0.1ml
抗體來(lái)源Rabbit
克隆類型Polyclonal
交叉反應(yīng) IgG
產(chǎn)品應(yīng)用IF=1:100-1000
not yet tested in other applications.
optimal dilutions/concentrations should be determined by the end user.
分 子 量25kDa
性 狀Lyophilized or Liquid
濃 度2mg/1ml
免 疫 原KLH conjugated synthetic peptide derived from mouse Kappa li
亞 型IgG
純化方法affinity purified by Protein A
儲(chǔ) 存 液0.01M TBS(pH7.4) with 1% BSA, 0.03% Proclin300 and 50% Glycerol.
保存條件Storage: Store at –20 oC for one year. Avoid repeated freeze/thaw cycles. The lyophilized antibody is stable at room temperature for at least one month and for greater than a year when kept at -20oC. When reconstituted in sterile distilled water or diluent supplied, theantibody is stable for at least two weeks at 2-4 °C.
相關(guān)資料:
產(chǎn)品介紹background:
Immunoglobulins belong to a group of related glyco proteins which make up 20% of serum proteins. Antigens and immunoglobulins react to confer immunity to individuals. Immunoglobulins have similar structures of two identical heavy chains and two identical light chains. Both the heavy chains and the light chains are divided into constant and variable regions. The constant regions have the same amino acid sequences between all the immunoglobulin classes. The variable regions have approximately 110 amino acids with high sequence variability. The amino acid sequence of the heavy chain determines the class of an immunoglobulin. The five types of immunoglobulin heavy chains are known as: IgG, IgA, IgM, IgD, and IgE. IgG is divided into four subclasses, and IgA is divided into two subclasses. In serum IgA and IgG are monomers with a single 4 polypeptide unit; while, IgM is a pen tamer. IgA may also form polymers. Kappa light chain antibody can be used for the identification of leukemias, plasmacytomas and certain non Hodgkin's lymphomas. Kappa light chain contains one immunoglobulin like domain. The EU sequence has the INV allotypic marker, Ala 45 and Val 83. The ROY sequence has the INV allotypic marker, Ala 45 and Leu 83.
Important Note:
This product as supplied is intended for research use only, not for use in human, therapeutic or diagnostic applications.